Welcome to Prosurge Lightning and Surge Protection manufacturer and solution provider!
Products

100kA T1CA Surge Protective Device ETL certified as per UL1449 4th edition

Product Name: 100kA T1CA Surge Protective Device ETL certified as per UL1449 4th edition
Part Series: V100E/XXX(-S)
Application: Railway system, lighting, PV system, Wind turbine, EV charging station etc
Description: Din rail type 1CA SPD with SCCR 200 kArms without external fuse or Circuit breaker. Imax 100kA 8/20. Pluggable design with window fault indication.

Features of V100E series:

Type1 CA surge protective device is especially designed for low-voltage powersupply system at the boundaries from lightning protection zone 1-2 and higher.

Ø         Short circuit current rating (SCCR) 200kA without external fuse or circuit breaker.

Ø         ETL certified surge protector according to UL1449-4th

Ø        Pluggable design with window fault indication

Ø         Nominal discharge current In 20kA 8/20, max dischargecurrent Imax 100kA 8/20

Ø         High reliability due to global patented thermally protected MOV (TMOV) with special arc-extinguish device.


Technical specification :

In accordance with

UL1449 4th

Category IEC/VDE

Type1CA

Max. continuous operating voltage 

V (AC/DC)

150

/200

180

/240

250

/330

275

/370

320

/420

420

/560

510

/670

550

/710

Nominal discharge current(8/20) In

20kA

Max. discharge current(8/20) Imax

100kA

Voltage protection rating

@ VPR

<0.7kV

<0.7kV

<1.0kV

<1.0kV

<1.2kV

<1.5kV

<1.5kV

<1.5kV

Response time

≤25 ns

Follow current

No

Backup fuse(only required if not already provided in mains)

125A gL/gG

Operating temperature range

- 40ºC ~ + 80ºC

Cross-section of connection wire

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

36mm width, DIN 43880

Thermal disconnector

Internal  green – normal ; red - failure

Remote alarm contact

Optional

SCCR rating

200kA

Approvals, Certifications

ETL/CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Max. Size of connecting wire

Max. 1.5mm2(or # 16AWG)


Modular combination guide:V100E/150(-S),V100E/180(-S),V100E/250(-S),V100E/275(-S),V100E/320(-S),V100E/420(-S) ,V100E/510(-S),V100E/550(-S) : Prosurge HIT UL listed Surge Protective Device, MCOV 150-550Vac, In20kA 8/20. With window fault indication.

Dimension & Circuit diagram :